What should I do if the floor heating is not hot?

2025-12-31 14:49:29 mechanical

What should I do if the floor heating is not hot? Comprehensive analysis of causes and solutions

With the advent of winter, the lack of heat in geothermal heating has become a focus of concern for many families. This article combines hot topics and user feedback from the entire Internet in the past 10 days to sort out the common reasons and solutions for why geothermal heaters are not hot, and provide structured data reference.

1. Common reasons why geothermal heating is not hot

What should I do if the floor heating is not hot?

Cause classificationSpecific performanceProportion (user feedback)
clogged pipesThe water distributor valve has a large temperature difference and is not hot locally35%
Insufficient air pressureSystem pressure is lower than 1.5Bar28%
filter cloggedThe inlet pipe is hot and the return pipe is cold20%
Thermostat failureThe display is abnormal or cannot be adjusted12%
other reasonsThe floor covering is too thick and has not been cleaned for a long time, etc.5%

2. Targeted solutions

1. Pipeline blockage treatment

• Close all valves of the water distributor and release water to flush each branch
• Use professional geothermal cleaning equipment (recommended to clean every 2 years)
• Check whether the pipes are obviously deformed or damaged

2. System pressure adjustment

Pressure value (Bar)Handling suggestions
<1.0Immediately replenish water to 1.5-2.0
1.0-1.5Observe 24-hour pressure changes
>2.5Pressure reduction via drain valve

3. Filter cleaning steps

① Close the main water inlet and return valve
② Use a wrench to open the filter end cover
③ Take out the filter and clean it with a toothbrush
④ Reinstall it as it is and slowly fill it with water and exhaust it.

3. Summary of recent hot issues (last 10 days)

Hot search keywordssearch volume indexmain areas
Geothermal return valve adjustment187,000Three Northeastern Provinces
Floor heating exhaust method152,000Beijing-Tianjin-Hebei
Water distributor valve repair98,000Jiangsu, Zhejiang and Shanghai
Geothermal cleaning price76,000Sichuan and Chongqing Region

4. Professional advice

1.Golden detection period: It is recommended to test the temperature between 6 and 8 o'clock in the morning, when the system operates most stably.
2.Temperature standard reference: The ground temperature should be in the range of 24-28℃, and the ideal room temperature is 18-22℃
3.Emergency treatment: If leakage is found in the pipeline, close the main valve immediately and contact professionals

5. Preventive maintenance calendar

monthmaintenance items
OctoberSystem water testing and pressure testing
NovemberRunning the exhaust for the first time
MarchShut down system maintenance
JuneAnnual deep cleaning

Through the above systematic analysis and solutions, we hope to help you effectively solve the problem of non-heating geothermal heating. If the problem persists, it is recommended to contact a professional floor heating repair service to avoid system damage caused by self-disassembly.

Next article
  • What does PSID mean?In today's era of information explosion, various abbreviations and terms emerge in endlessly, among whichPSIDIt is a word that is often mentioned but not well understood by many people. This article will explain in detail the meaning, application scenarios and related hot topics of PSID, and help readers better understand it through structured data.1. Definition of PSIDPSIDYesPersonal Secure Ident
    2026-01-25 mechanical
  • Which tiles are cost-effective? Buying guide for popular ceramic tiles on the InternetRecently, the purchase of ceramic tiles has become one of the hot topics in home decoration. Especially during the peak decoration season, consumer demand for cost-effective ceramic tiles has surged. This article will combine the hot content on the Internet in the past 10 days and analyze it from multiple dimensions such as price, m
    2026-01-22 mechanical
  • What is negative sequence voltage?In power systems, negative sequence voltage is an important concept, especially when analyzing asymmetric faults or load imbalances. This article will introduce in detail the definition, causes, effects, and related measurement and solution methods of negative sequence voltage.1. Definition of negative sequence voltageNegative sequence voltage refers to the component of the voltage p
    2026-01-20 mechanical
  • What does dry contact mean?In the field of electrical engineering and automation control, "dry contact" is a common professional term, but it may be unfamiliar to non-professionals. This article will combine the hot topics and hot content on the Internet in the past 10 days to explain in detail the definition, application scenarios and differences between dry contacts and other contacts, and help readers better under
    2026-01-18 mechanical
Recommended articles
Reading rankings
Friendly links
Dividing line